DOUT1.MODE and DOUT2.MODE
DOUT1.MODE
Description
DOUTx.MODE sets the functionality of the digital output(s).
|
DOUTx.MODE |
Description |
|---|---|
|
User (default = 0) |
|
|
Mains ready |
|
|
Software limit switch reached |
|
|
Move complete |
|
|
In position |
|
|
Position greater than x |
|
|
Position less than x |
|
|
Drive produced warning |
|
|
Drive enabled |
|
|
Reserved |
|
|
Motor brake |
|
|
Drive produced fault |
|
|
Absolute velocity greater than x |
|
|
Absolute velocity less than x |
|
|
Programmable Limit Switch Output |
|
| 16 | Command Buffer Active |
| 17 | Mt in Position |
| 20 | Controlled Stop Active |
| 21 | Immediate Fault Disable |
| 22 | In Rush Relay State |
| 23 | Compare Output |
| 24 | STO Status |
| 25 | W&S Done |
| 27 | Warning Number |
General Information
|
Type |
NV Parameter |
|
Units |
N/A |
|
Range |
0 to 8, 10 to 17, 20 to 25, 27 BASIC: 0, 8, 10, 11, 15, 22, 23, 25 AKD-C: 0, 1, 7, 11,16, 22, 27 AKD-N: 0 to 8, 10 to 17, 20, 21, 25, 27 EtherNet/IP: 0 to 2 |
|
Default Value |
0 |
|
Data Type |
Integer |
|
Start Version |
M_01-04-02-000 |
| Fieldbus |
Index/Subindex | Object Start Version | |
|---|---|---|---|
|
/0 |
DOUT1.MODE |
M_01-04-02-000 | |
|
/0 |
DOUT2.MODE |
||
Related Topics